Product Watch
Stat Diagnostics' Heliprobe TM
Heliprobe TM is a "Urea breath test"
Since
Barry Marshall described the Helicobacter pylori (H.pylori) and its role in
different gastrointestinal diseases, an intense research effort has developed
different diagnostic methods. The only nonivasive test method that can be clinically
used as a diagnostic tool for on-going infection with H.pylori and post-eradication
follow-up is the "urea breath test". Different serological tests are
available, but they cannot determine the actual status of the infection and
can therefore only be used for screening tests. With the Radprobe TM, a cost-effective
test is available, easy to use in the doctor's office.
How does Heliprobe TM work?
The Urea Breath Test method (UBT) Is based on the fact that
the bacteria H. pylori produces an enzyme, urease, which catalyzes the hydrolysis
of the urea molecule into ammonium and carbon dioxide.H. plyori requires the
alkaline ammonium in order to establish an optimal local mucosal environment
within the acidic environment of the stomach. The urea compound is an endogenous
substance that contains one carbon atom, normally C, which can be replaced by
its isotope C or C. Heliprobe TM uses the isotope C which has very low B-radioactive
emission. The radioactive dose used for a Heliprobe TM test is 1 uCurie, which
is significantly less than the radioactive dose given at a normal X-ray examination
of the stomach, and equal to a few glasses of orange juice.
A Helicap is ingested with 50 ml of water. If an infection with H. pylori is
present in the stomach, the "living" bacteria produces the enzyme
"urease" that metabolizes the C-urea into ammonium and carbon dioxide
containing the C-labelled atoms. The carbon dioxide will be assimilated through
the mucosa into the blood stream and transported to the lungs where it is exhaled.
By collecting the exhaled carbon dioxide in the BreathCardTM, the amount of
Co2 produced in the stomach can be measured with the Heliprobe TM instrument.
If the patient is not infected, no metabolization of urea will occur and therefore
no CO2 can be detected with the Heliprobe TM system. In this case the unmetabolized
C urea will pass along the digestive canal to be excreted in the urine. If the
Heliprobe TM system detects Co2 this is diagnostic evidence of an ongoing infection
with living H.pylori. Heliprobe TM is developed for primary diagnosis of H.
pylori, as well as for follow-up after eradication treatment.
Laboratory and Clinical Evaluation
To ensure equivalent results comparable with sophisticated, well-established
laboratory techniques used for scientific purposes, the following comparison
between Heliprobe TM and liquid scintillation for C detection was made. A Laboratory
set-up (simulating the patient) with controlled parameters according to figure
1 was established. The result of the comparison was statistically analyzed applying
linear regression. The outcome of the analysis shows a regression line with
high correlation between these methods as presented in figure 2. Clinical Validation
studies involving more than 400 patients has also been performed at the Karolinska
University Hospital in Stockholm, Sweden.
Stat Diagnostics Services
3rd Floor, Chandrapushpa Building
Opp. New Post Office
Hirachand Desai Marg
Ghatkopar (West)Mumbai-86
Tel: 91-22-25112424, 91-22-25157206
Allied Healthcare's Bpdy Guard 323
BodyGuard
323 multi programmable infusion pump offers advanced facilities in infusion
pump. The pump has different user selectable programs like Continuous infusion,
TPN, 25 Steps, Sinusoidal and PCA. Patient Controlled Analgesia (PCA) is a program
used for patients who require IV pain management or epidural analgesia. Pain
management is undertaken by delivering a continuous basal rate in combination
with pre programmed boluses. The pump will deliver the boluses corresponding
to the preset time intervals. All attempts to obtain boluses are stored in the
pump memory. The physician can read these statistics and adjust the setting
as required. It is possible to set and store up to 5 different protocols for
PCA including names of drugs. The cable and switch provided with machines enables
the patient to activate the bolus incase of emergency without accessing the
key pad switches. A safety lock out time can be programmed on the machine to
limit the use of such bolus infusion by patient.
BodyGuard 323 a highly compact light weight (Just 320gm) with out battery is
an FDA approved pump for precise infusion of medication and fluids requiring
continuous or intermittent delivery through clinically acceptable routes of
administration including intravenous, subcutaneous, percutaneous, interarterial,
epidural and enteral.
The equipment is intended for patients who require maintenance medication, analgesics,
PCA therapy paranteral and enteral nutrition fluids, chemotherapeutic agents
and general fluids therapy in hospital and homecare environments. The BodyGuard
comes in two parts. The pump and charger and is fitted with rechargeable Li-ion
battery. A fully charged battery will run the pump for 175hrs @ 1 ml/hr or 35hrs
@ 15ml/hr. BodyGuard pump has a unique piston pumping mechanism the flow rate
is 0.1ml to 100ml/hr in with 0.1ml increments in PCA mode and 0.1 to 1200ml/hr
in other modes. It has got a provision for a total time setting of 100hrs and
the accuracy is ± 3%. This pump comes with a comprehensive range of alarm
conditions for any malfunction with error nature displayed on the screen. The
pump has got wide acceptance and appreciation from major hospitals
India Distributor:
Allied Healthcare India
3, Arumugam Street,Mount Road,
Chennai - 600 002
Ph : 044 28606418/28600259
Fax: 044-28601530
Email : ahci@dataone.in
HMS Medical Systems' UNISTIM
UNISTIM
offers a choice of 12 current types
- Four-pole interferential therapy with or without
vector scan
- Bipolar interferential therapy
- TENS continuous current
- TENS Burst current
- Rectangular pulsed current
- Triangular pulsed current
- Ultra Reiz current
- Galvanic direct current
- DF - Diphase Fixe
- MF - Monophase Fixe
- CP - Module en courtes Periodes
- LP - Module en Longues Periodes
Features
- Both medium and Low frequency currents
- 64 Pre-programmes condition wise with protocols
- Cable and Electrode checking mode
- User settable memory
- Light weight and compact design
- Easy to operate
- Future upgrade without change in hardware
- DSP Based circuitry, outputs are in 100% accuracy
- Large graphic LCD Display
- International standards and specifications
- Advanced patient safety system
- PC Interface facility (in future)
Technical Modification Reserved
HMS Medical Systems
2-A, Iind floor, Jaidurga Complex, New No. 60, 1st Avenue, 100 Feet Road,
Ashok Nagar,
Chennai - 600 083.
Tel: 91 - 44 - 2474 0735 / 4231 8090
Telefax: 91 - 44 - 2371 3144
Website : www.hms.co.in
E-mail : hms_chennai@vsnl.net
sales@hms.co.in
PLASMA FREEZER BY SKYLAB
LABTOP
micro controller based Plasma Freezers are designed for quick freezing and storing
of plasma and related blood components at desire low temperature up to -35C.
the system include temperature controller with digital temperature display,
Temperature recorder, ON / OFF switch, Temperature alarm system with adjustable
high / low alarm limits, includes audio visual alarm on the temperature deviation.
Cabinet Construction and Refrigeration System
High density CFC Free Poly Urethane Foam insulated cabinet with corrosion resistant
stainless steel interior, White powder coated exterior finish, Keyed door lock
for improved security with magnetic door gasket Open stainless steel plasma
basket, Air-cooled hermetically sealed compressor.
Optional Accessories
- RS-485 interface for multiple networking.
- Multi channel with data logging system.
- Mobile alert via GSM technology in case of system
failure.
LABTOP REFRIGERATORS BY SKYLAB
LABTOP
Laboratory refrigerators are available in a variety of configurations providing
alternatives between cabinet capacity, control capability.
General Feature: Applications include refrigerated
storage of vaccines, Reagents, Cultures, Medicines and Blood samples. Temperature
range adjustable from 2.0C to 8.0C with micro controller based temperature controller
includes digital temperature display of set value and process value, Forced
air circulation for maximum temperature uniformity. Temperature alarm system
with adjustable high / low alarm limits, includes audible and visual warning.
Cabinet Construction and Refrigeration System:
High density CFC Free Poly Urethane Foam insulated cabinet with corrosion resistant
stainless steel interior white powder coated exterior finish, Keyed door lock
for improved security with magnetic door gasket, Open stainless steel utility
basket, Air-cooled hermetically sealed compressor.
- Micro-controller controls the internal temperature
within + 0.5C
- Unique air flow system ensures even temperature
distribution.
- Foamed-in-place CFC free PUF insulation ensures
temperature stability and reduced energy consumption.
- Audio visual alarm when the temperature deviates
from the pre set temperature.
- Display of set value and process value.
- Specially designed Stainless steel basket ensure
even temperature distribution.
- Directional air flow assures quick recovery after
door openings.
SkyLab Instruments & Engineering Pvt. Ltd.
M-7&8, Anand Mangal Ind. Estate, Survey No.:70-B
Opp.IPOL, Waliv Phata, Sativali Road
Vasai (East), Dist-Thane-401208
Maharashtra, India
Tel: 91-250-2481431, 2481428
E-mail: byjuskylab@vsnl.net
Website: www.skylabinstrument.com
NICE NEOTECHS ORCHID 3000
The
nice ORCHID 3000 - Transport Baby Incubator is a Microprocessor Controlled System
with Air and Skin Modes of operation, with the following features:
- Displays Air / Skin Temperature simultaneously
with Set temperature.
- Feather Touch operation with large digital display
and comprehensive alarms.
- Memory backup to restore set temperature and control
mode automatically in the event of power failure.
- An integral and with drawable baby tray to aid resuscitation
during transport.
- An integral Humidifier.
- Internal battery Backup for 4 hours minimum. Operates
both on AC and DC currents, with visual indication for battery power status
and power sources.
- Collapsible stainless steel stand with shock absorbers.
- Dual Thermistor Temperature Probes, with accuracy
of +0.2°C, to minimize down time and ensure accuracy. Probe interchangeable
without calibration.
- A, 2D (or) 2E tank mounting facility to mount gas
cylinders.
- Unimpeded access to the patient with frontal access
and a minimum of 2 access ports and three elbow operated ports.
- Easy to clean and disinfect.
- High Intensity CFL Light for observation.
- Comprehensive alarms and Safety features.
- O2 Driven Venturi Slow Suction with humidified O2.
- Accessories Include: 'A' type cylinder, Pressure
Regulator Assembly, IV Stand, Auxiliary Tray Shelf for other placing additional
equipment. Flow meter, O2 Cylinder, O2 Failure Alarm.
nice Neotech Medical Systems Pvt. Ltd.
85-86, Krishna Industrial Estate
Vannagaram, Mettukuppam,
Chennai 600 095
Phone: 044-24764608
Fax: 044-24762594
E-mail: marketing@niceneotech.com,
Website: www.niceneotech.com
GAYATRI SURGICAL EQUIPMETS AUTA
We
feel great pleasure to introduce ourselves as one of the leading manufacturer
of latest high quality range of Anaesthesia Apparatus & O.T.Equipment in
India. We started our production of Anaesthesia Apparatus at MIDC Tarapur Dist.
Thane of Maharashtra with latest in house Manufacturing facilities and modern
testing method. Later due to Doctors confidence on our quality product, our
efficient after sales service & their over wheiming response we also started
manufacturing O.T. Equipment viz. Hydraulic Table, Halogen Lights, Gautery Suction
etc. Today our GSE-Anaesthesia Apparatus range is ISI 11378:2002 mark approved
and it complies to all ISI and ISO norms. Also our manufacturing process &
facility is ISO 9001 certified. Our aim and commitment to manufacture high quality
& ergonomically designed Anaesthesia Apparatus & O.T. Equipment is ensured
by our quality management system which is in compliance with ISO 9001:2000 which
was duly certified. The advice feed back and consultation with Doctors and our
continuous R&D has enabled us to manufacture a comprehensive range that
suits various needs of our clients. Hence we have introduced 'Auta' a complete
new range of Advance Anaesthesia workstation. Our philosophy to give the customer
the most economical solution to their requirement in the shortest possible time
frame with the best quality is reinforced by a commitment and dedication wide
quality from designing to efficient after sales services. Our efficient after
sale service is ensured by our network of Local Designs / Representatives all
over India. The result is that today we have more than 1000 Specialised Hospitals,
Nursing Homes, General Hospitals, Government Hospitals and Medical institution
using our Apparatus with complete confidence.
Gayatri Surgical Equipment
Plot No.7 Shukla Compound Avadh Nagar,
Navapur Road
Dist.-Thane, Boisar - 401501,
Tel: 02525 278887
|