Product Watch
Stat Diagnostic Services
Captus 3000 Thyroid Uptake System 7 well System
Performing
thyroid uptake measurements has never been easier. The Captus 3000 combines
a totally new software programme with the latest PC technology to create a thyroid
uptake system that is fast, reliable and extremely easy to use. The Captus software
has been designed to get you up and running in virtually no time at all. The
programme contains a 'quick - start' feature that walks the user thought all
of the initial setup functions. The 'quick - start' feature also serves as an
excellent teaching tool. The Captus 3000 software is a full service programme
with thyroid uptake, wipe testing, bioassay, schillings, dicopac, blood volume
and RBC survival functionality built in the Wipe Test module has been a 'new'
feature that allows the flexibility of predefined or user defined groupings.
The entire programme has 'fly over' control bars to allow quick access to whatever
function is necessary. QA is, of course, completely automated and now includes
a 'new' feature for measuring Minimum Detectable Activity with the use of the
two included reference standards (Cs-137 and Eu-152), the system will move from
calibration to constancy to chi-square with limited time and effort. There is
a new and versatile 1024 Multichannel Analyser (MCA) module that allows measurements
of energies up to 2 MeV. The MCA module also has an isotope and adjustable ROIs
for reproducible counting parameters. As always, the entire system comes with
Capintec's unsurpassed quality construction and customer service. For installation
and training to applications support, just call 800-631-3826 to speak to a technical
support specialist.
Features:
- Thyroid Uptake.
- Bioassay.
- Lab tests.
- 1024 Multichannel analyser.
- Flexible pre-defined or user-defined wipe test groupings.
- Improved data storage, archive and reporting functions
'quick start' menu.
- Automated QC functions, including energy calibration.
- Constancy, X2 and MDA.
- 360 degree Articulating Spring Arm.
Contact:
Stat Diagnostic Services
3rd Floor, Chandrapushpa Building
Opposite New Post Office
Hirachand Desai Marg,
Ghatkopar (West)
Mumbai-86
Tel: 91 22 25112424 / 25157206
Email: info@statnuclear.com
BPL LTD
Biphasic Defibrillator DEFI-ART SERIES
BPL
Healthcare, a division of the BPL Limited, has launched DEFI-ART, a series of
Biphasic Cardiac Defibrillators for use in hospitals and in Public Areas.
DEFI-ART Biphasic Defibrillator DF2617 will be manufactured
under technology collaboration with Corscience GmbH, Germany and sold in India
by BPL. It is based on an optimised constant current controlled waveform that
has been proven to deliver much better results than the conventional defibrillators.
Key Features:
- Current controlled Bi-Phasic waveform. CE certified
technology from Germany.
- More than 100 charge/discharge of 300 Joules with
fully charged new battery.
- 24 Event recording.
- Bright backlit LCD for sharp display.
- Remote charging through paddles.
- Sliding adult electrodes over paediatric electrodes
for easy use.
- On screen indicator of paddle to patient contact.
- 50mm recorder.
Contact:
BPL LTD
Healthcare Business Group
BPL Towers,
13, Kasturba Road
Bangalore-560001
India
Tel:+91-80-22270134
Fax: +91-80-22275641
Website: www.bpl.in/healtcare
Email: sales.healthcare @bpl.in
Schiller India
Defigard 400 Multi-Pulse Biphasic Defibrillator
Schiller
India, a leading Swiss joint venture company in the field of medical diagnostics,
has launched a new defibrillator called Defigard 400, India's first indigenously
manufactured multi-pulse biphasic defibrillator.
The Defigard 400 Defibrillator uses Schiller's patented and
highly successful, multi-pulse biphasic current. This technology is widely preferred
in the advance market as it results in lower tissue damage to the patient's
heart and facilitates faster recovery.
Features of Defigard 400:
- Large 6.4" colour TFT screen.
- Suitable for adult and paediatric application.
- Multi-pulse Biowave technology for external defibrillation.
Selectable from 1 to 180J.
- Visual instructions and simple three steps operation.
- Three channel memory.
- 24 hours ECG.
- Last 11 shocks data saved.
- Trim knob and direct function keys for print, mute
and freeze.
- Digital out for ECG data to central monitoring station.
- Integrated thermal printer with auto and manual modes
(optional).
Contact:
Hansa Soneji
Product Specialist
Schiller Healthcare India Pvt Ltd
D.C. Silk Mills Compound
Kondivitta Lane
Andheri East
Mumbai - 400 059
Tel: 022 6692 0520
Fax: 022 2826 3525
Email: hansa@schillerindia.com
|